MB-2T |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Availability |
 |
 |
 |
available |
 |
 |
 |
 |
 |
 |
 |
Product description |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Description |
 |
 |
 |
Expansion backplane with 2 slots for MS20/30-16 and MS4128 MICE switches |
 |
 |
 |
 |
 |
 |
 |
Port type and quantity |
 |
 |
 |
2 slots integrated on backplane (8 ports possible via media modules) |
 |
 |
 |
 |
 |
 |
 |
Type |
 |
 |
 |
MB-2T |
 |
 |
 |
 |
 |
 |
 |
Order No. |
 |
 |
 |
943 733-102 |
 |
 |
 |
 |
 |
 |
 |
Power requirements |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Power consumption |
 |
 |
 |
0 W |
 |
 |
 |
 |
 |
 |
 |
Ambient conditions |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Operating temperature |
 |
 |
 |
0 ºC bis +60 ºC standart ( optional -40ºC to +70ºC) |
 |
 |
 |
 |
 |
 |
 |
Storage/transport temperature |
 |
 |
 |
-25 ºC to +70 ºC |
 |
 |
 |
 |
 |
 |
 |
Protective paint on PCB |
 |
 |
 |
optional |
 |
 |
 |
 |
 |
 |
 |
Relative humidity (non-condensing) |
 |
 |
 |
10% to 95% |
 |
 |
 |
 |
 |
 |
 |
MTBF |
 |
 |
 |
1146.1 years; MIL-HDBK 217F: Gb 25 ºC |
 |
 |
 |
 |
 |
 |
 |
Mechanical construction |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Dimensions (W x H x D) |
 |
 |
 |
79 mm x 134 mm x 22 mm |
 |
 |
 |
 |
 |
 |
 |
Mounting |
 |
 |
 |
DIN Rail 35 mm |
 |
 |
 |
 |
 |
 |
 |
Weight |
 |
 |
 |
150 g |
 |
 |
 |
 |
 |
 |
 |
Protection class |
 |
 |
 |
IP 20 |
 |
 |
 |
 |
 |
 |
 |
Mechanical stability |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-27 shock |
 |
 |
 |
15 g, 11 ms duration, 18 shocks |
 |
 |
 |
 |
 |
 |
 |
IEC 60068-2-6 vibration |
 |
 |
 |
1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
 |
 |
 |
 |
 |
 |
 |
EMC interference immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-2 electrostatic discharge (ESD) |
 |
 |
 |
6 kV contact discharge, 8 kV air discharge |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-3 electromagnetic field |
 |
 |
 |
10 V/m (80 - 1000 MHz) |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-4 fast transients (burst) |
 |
 |
 |
2 kV power line, 1 kV data line |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-5 surge voltage |
 |
 |
 |
Power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
 |
 |
 |
 |
 |
 |
 |
EN 61000-4-6 conducted immunity |
 |
 |
 |
3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
 |
 |
 |
 |
 |
 |
 |
EMC emitted immunity |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
FCC CFR47 Part 15 |
 |
 |
 |
FCC CFR47 Part 15 Class A |
 |
 |
 |
 |
 |
 |
 |
EN 55022 |
 |
 |
 |
EN 55022 Class A |
 |
 |
 |
 |
 |
 |
 |
Approvals |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Safety of industrial control equipment |
 |
 |
 |
cUL 508 (E175531) |
 |
 |
 |
 |
 |
 |
 |
Hazardous locations |
 |
 |
 |
cUL 1604 Class 1 Div 2 (E203960) |
 |
 |
 |
 |
 |
 |
 |
Germanischer Lloyd |
 |
 |
 |
optional |
 |
 |
 |
 |
 |
 |
 |
Railway norm |
 |
 |
 |
optional |
 |
 |
 |
 |
 |
 |
 |
Substation |
 |
 |
 |
optional |
 |
 |
 |
 |