Electronic Control Systems
Industrial Connectors
Industrial Networking
Industrial Ethernet
OpenRail System
RSR
Rail Family
MICE
Switches
ETHERNET / Fast-ETHERNET Media Modules
Realtime Modules
Gigabit ETHERNET Media Modules
ETHERNET / Fast-ETHERNET POF media modules
Accessories
EAGLE System
Wireless LAN
OCTOPUS IP67
RS40 Full Gigabit
MACH100
MACH 1000
MACH 3000
MACH 4000
LION Control Room Switch
Network Management
System Accessories
Powerlink Router
Rail Video
Transceiver
FiberINTERFACES
Hirschmann Competence Center
 
  Reference product Selected variant
  MM4-2TX/SFP M-SFP-LH+/LC
Availability available available

Product description

Description Media module for MICE Switch MS4128, MS30xx,
10/100/1000BASE-TX und 1000BASE-SX/LX
SFP Fiberoptic Gigabit Ethernet Transceiver for: MICE media modules, MM4-4TX/SFP and MM4-2TX/SFP, OpenRail RS30-Switches, MACH 4002 48+4G, SmartLION and GigaLION.
Port type and quantity 2 x 1000BASE-fiber with SFP modules, or
2 x 10/100/1000BASE-TX, TP cable, RJ45-sockets, autocrossing, autoneg., autopolarity
any combination TX or SFP, 1 SFP deactivates 1TX, up to 2 ports
1 x 1000BASE-LX with LC connector
Type MM4-2TX/SFP M-SFP-LH+/LC
Order No. 943 622-001 943 049-001

Network size - length of cable

Twisted pair (TP) 0 - 100 m
Multimode fiber (MM) 50/125 µm cf. SFP module M-SFP-SX/LC and M-SFP-LX/LC same as reference variant
Multimode fiber (MM) 62.5/125 µm cf. SFP module M-SFP-SX/LC and M-SFP-LX/LC
Single mode fiber (SM) 9/125 µm cf. SFP module M-SFP-LX/LC same as reference variant
Single mode fiber (LH) 9/125 µm (long haul transceiver) cf. SFP FO module M-SFP-LH/LC and M-SFP-LH+/LC 44 - 120 km
13 - 32 dB link budget at 1550 nm
A = 0.25 dB/km, 2 dB reserve, D = 19 ps/(nm x km)

Power requirements

Operating voltage power supply via the backplane of the MICE switch power supply via the switch
Power consumption 2 W 1 W

Service

Diagnostics LEDs (power, link status, data, 1000 Mbit/s, auto-negotiation, full duplex, ring port, LED test) optical input and output power, transceiver temperature

Ambient conditions

Operating temperature 0 ºC bis +60 ºC standart ( optional -40ºC to +70ºC) 0 ºC to +60 ºC
Storage/transport temperature -40 ºC to +70 ºC -40ºC to +85ºC
Protective paint on PCB optional
Relative humidity (non-condensing) 10% to 95% same as reference variant
MTBF 163 years; MIL-HDBK 217F: Gb 25 ºC

Mechanical construction

Dimensions (W x H x D) 38 mm x 134 mm x 77 mm 20 mm x 18 mm x 50 mm
Mounting Backplane SFP slot
Weight 160 g 40 g
Protection class IP 20 same as reference variant

Mechanical stability

IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks same as reference variant
IEC 60068-2-6 vibration 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz,
10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
same as reference variant

EMC interference immunity

EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge same as reference variant
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) same as reference variant
EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line same as reference variant
EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line same as reference variant
EN 61000-4-6 conducted immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) same as reference variant

EMC emitted immunity

FCC CFR47 Part 15 FCC CFR47 Part 15 Class A same as reference variant
EN 55022 EN 55022 Class A same as reference variant

Approvals

Safety of industrial control equipment cUL 508 (E175531) same as reference variant
Hazardous locations cUL 1604 class1 div2 cUL 1604 Class 1 Div 2 (E203960)
Germanischer Lloyd optional Germanischer Lloyd (43 109-02 HH)
Railway norm optional
Substation optional

Scope of delivery and accessories

Scope of delivery module, operating manual SFP module
Accessories to order separately ML-MS2/MM labels
Downloads
Manual
Description and operating instructions MICE media modules open variant , V.1.0 (31.01.2007)
download Anl_MICE_Module_OV_01_en.pdf   (472 KB)
Description and operating instructions MICE media modules open variant (German), V.1.0 (31.01.2007)
download Anl_MICE_Module_OV_01_de.pdf   (465 KB)
Handbuch Grundlagen Local Area Network (LAN) (german), 1.0 (23.04.2001)
download HBGrundlagede.pdf   (1.34 MB)
Manual Basics Local Area Network (LAN) (english), 1.0 (23.04.2001)
download HBGrundlageus.pdf   (1.24 MB)
Mounting instructions
Description and operating instructions MICE media modules open variant, 06 (04.11.2008)
download Anl_MICE_Module_OV_06_1108_en.pdf  (953 KB)
Description and operating instructions MICE media modules open variant (German), 06 (04.11.2008)
download Anl_MICE_Module_OV_06_1108_de.pdf  (949 KB)
Catalog
Catalog Industrial Ethernet English, Edition 6 (19.11.2008)
download Katalog_INET_en.pdf  (10.2 MB)
Catalog Industrial Ethernet German, Edition 6 (19.11.2008)
download Katalog_INET_de.pdf  (13.6 MB)
Flyer
Power MICE, Ausgabe 1 (01.08.2004)
Wer im ETHERNET etwas bewegen will, muss in Gigabit denken: Die neue Power MICE
download flyer_powermice_de.pdf  (1.10 MB)
Power MICE, Edition 1 (01.08.2004)
In the ETHERNET arena, the movers and shakers think in Gigabits: The new Power MICE
download flyer_powermice_us.pdf  (1.11 MB)
Brochure
Pocket Guide - Industrial Ethernet (english), Edition 2006 (01.03.2006)
download pocket_guide_us.pdf  (1.86 MB)
Pocket Guide - Industrial Ethernet (german), Edition 2006 (01.03.2006)
download pocket_guide_de.pdf  (1.84 MB)
Kurzanleitung
Beschreibung und Betriebsanleitung MICE (german), V.1.0 (28.04.2005)
download Anl_PowerMICE_de.pdf  (502 KB)
Description and Operating Instructions MICE (english), 3.0 (28.04.2005)
download Anl_PowerMICE_us.pdf  (495 KB)
Visio Shapes
Visio Shapes MICE, Version 10/04 (01.10.2004)
Visio Shapes MACH 3000
download vi_Hirschmann_MICE-Family 0410.zip  (606 KB)
Manufacturer Declaration of Conformity
Germanischer Llyod Certificate, 1.0 (11.01.2006)
Compliant with the GL Type Approval System
download KE_GL_2668905_06-01-11.pdf  (221 KB)
FAQs
Service / Accessories
What is the Pin-Assignement of the MACH, MICE, RS2 terminal cable?
see download link
terminal cable, 1.0 (21.01.2005)
Pin Assignment of the terminal cable
Terminalkabel.pdf   (83.7 KB)
What is the maximum current supported by the indicator contact?
1A / 24V
Variants selection

Selection by product name
You already know the name for your requested product.

Legend

= variant feature

= different feature
   
[^]